As the 1 auxiliary equipment of clean room, the pass box is mainly used for the transmission of small items between clean area and clean area, non-clean area and clean area, so as to reduce the opening times of clean room and minimize the pollution of clean area. pass boxs are widely used in micro-technology, biological laboratories, pharmaceutical factories, hospitals, food processing industries, LCD, electronics factories and other places that need air purification.

Pass Box

The pass box is made of stainless steel plate, flat and smooth. The two doors are interlocked with each other to effectively prevent cross-contamination. They are equipped with electronic or mechanical interlocking devices and equipped with ultraviolet germicidal lamps.

The pass box is divided into 3 categories:

1. Electronic chain pass box.

2. Mechanical interlocking pass box.

3. Self-cleaning delivery window.

According to the working principle, the pass box can be divided into air shower type pass box, ordinary pass box and laminar flow pass box. Various types of pass boxs can be made according to actual requirements.

Optional accessories: walkie-talkie, germicidal lamp and other related functional accessories.

 

Features

1. The countertop of the short-distance pass box is made of stainless steel plate, which is smooth, smooth and wear-resistant.

2. The work surface of the long-distance pass box adopts an unpowered roller, which makes it easy and convenient to transmit items.

3. The doors on both sides are equipped with mechanical interlocking or electronic interlocking and electronic locking devices to ensure that the doors on both sides cannot be opened at the same time.

4. Various non-standard sizes and floor-to-ceiling pass boxs can be customized according to customer needs.

5. The wind speed at the air outlet of the air nozzle is as high as over 20s.

6. High-efficiency filter with partition plate is adopted, and the filtration efficiency is 99.99% to ensure the purification level.

7. EVA sealing material is adopted, with high sealing performance.

8. Pairable call walkie-talkie.

Usage

The pass box shall be managed according to the cleanliness level of the higher-level clean area connected with it. For example, the pass box connected with the filling room shall be managed according to the requirements of the filling room. After work, the operator of the clean area shall be responsible for wiping clean the internal surfaces of the pass box and turning on the ultraviolet sterilization lamp for 30 minutes.

1. The material entering and leaving the clean area must be strictly separated from the flow passage, and the material entering and leaving the production workshop must be the special passage.

2. When the materials enter, the raw and auxiliary materials shall be taken off the package or cleaned by the person in charge of the preparation process, and then sent to the temporary storage room of the raw and auxiliary materials of the workshop through the pass box. After the outer package is removed from the outer temporary storage room, the inner package materials are sent to the inner package room through the pass box. The workshop integrator and the person in charge of the preparation and internal packaging process handle the material handover.

3. When transmitting through the pass box, the regulation of “1 opening and 1 closing” of the inner and outer doors of the pass box must be strictly implemented, and the two doors cannot be opened at the same time. After the outside door puts the materials in, the door is closed first, and then the inside door puts the materials out and closes the door, thus circulating.

4. When the materials in the clean area are sent out, the materials shall be transported to the relevant material intermediate station first, and moved out of the clean area according to the opposite procedure when the materials enter.

5. All semi-finished products transported from the clean area shall be transported from the delivery window to the outer temporary storage room and transferred to the outer packaging room through the logistics channel.

6. Materials and wastes that are extremely prone to pollution shall be transported to non-clean areas from their special pass boxs.

7. After the materials enter and exit, the site of each clean room or intermediate station and the hygiene of the pass box shall be cleaned in time, the inner and outer passage doors of the pass box shall be closed, and the cleaning and disinfection work shall be done well.

 

Precautions

1. The pass box is suitable for general transportation. During transportation, it prevents rain and snow from invading to avoid damage and corrosion.

2. The pass box should be stored in a warehouse with a temperature of -10 ℃ ~ +40 ℃, a relative humidity of not more than 80%, and no corrosive gases such as acid and alkali.

3. When unpacking, should be civilized work, no rough, barbaric operation, so as not to cause personal injury.

4. After unpacking, please confirm whether the product is the product, and then carefully check the contents of the packing list for missing parts and whether the parts are damaged due to transportation.

Operational specifications

1. Wipe the items to be delivered with 0.5% peracetic acid or 5% iodophor solution.

2. Open the outer door of the pass box, quickly place the items to be transmitted, spray and disinfect the pass box with 0.5% peracetic acid, and close the outer door of the pass box.

3. Turn on the ultraviolet lamp in the pass box and irradiate the objects to be transmitted for not less than 15 minutes.

4. Notify the experimenter or staff in the barrier system, open the inner door of the pass box, and take out the items.

5. Close the inboard door of the pass box.